- From
the home screen click “SETUP”
- Click
“SETTING”
- Click
“PRINTER”
- Click
“PIXEL CORRECTION”
- At the
bottom of the screen click “DETAILED ADJUSTMENT”
- At the
right side of the screen click “USER VALUE REGISTRATION”
A screen will pop up asking
“REGISTER?”
Click “YES”
- Click
“PRINT BY ODD/EVEN NORMAL”
This will print the test that you will use to
perform the ODD/EVEN calibration.
- While
waiting for the test to come out use the windows key on the keyboard and
go to
Start
Programs
MUCS
This
will start the uniformity software.
- When
the MUCS program opens, click “ODD/EVEN CORRECTION”
The next 4 screens should already
have DEFAULT values specific to your machine. If you are unsure about these
settings please contact
QD technical support at
1-800-762-8088. Otherwise use the default values. They should appear as
follows:
MUCS
2 –Click “NEXT”
TYPE
2 – Click “NEXT”
Select
scanner type (If you’re scanner is not listed select “OTHER” then click “END”
A
SHEET – Click “DETERMINATION”
Click
“DETERMINATION”
This
will open the Microtek Scansuite.
- Double
click the Microtek Scan Wizard (The Wizards Hat)
- Lay
the test print on the flat bed scanner with the cyan bar to the left side
of the scanner, face down and not all the way to the bottom of the
scanner.
- Click
“Preview”
- Once
the preview is displayed, Drag the dotted lines around the preview image
as in the display making sure to include all of the cyan bar and all of
the yellow bars (including a little of the white area of the print), and a
little of the black portion at the top and bottom of the test print.
- If
you’re scanner is an X6EL then you must make sure that the “Width” total
sum is divisible by 3. For Example:
- Width
= 4509 (4+5+0+9=18) This Number
“18” is divisible by 3. If it is not divisible by 3 then alter the
numbers to get a number divisible by 3.
- Click
“Scan”
- Click
“Save” (temp.tif)
Do You Want To Replace? Click
“YES”
You may also get a message about
the hard drive. Click “Yes”
- Once
the scan is complete WAIT FOR THE SCANNER TO RESET TO THE HOME POSITION!
Once the scanner has stopped close the
Scanner preview and scansuite.
(the little guy in the lower left corner)
- In a
few moments a box will appear – Click “START OF CORRECTION”
- When
this is complete another window will appear titled “IN CALCULATION OF
CORRECTION VALUE”
Click “ALL YES and “DETERMINATION”
- Click “END”
This should take you back to the “PIXEL CORRECTION VALUE ADJUSTMENT”
screen.
- Click “RENEWAL
OF PIXEL CORRECTION” in the top right side of the screen.
- Click “YES”
to register the new values.
If you get an error about the HEAD=R
FILE Click “CONTINUE”
You have now